- C3: 22 detected component lines evened (edge-gap distribution between line
endpoints), 58 parts nudged; everything touched by the hand-routed 24V/IGN
tracks frozen (P1,Q10,D10,DzG1,C10,C11,C22,Rig1,Ren1,U2)
- C4: finer pass — pairs included (33 lines total, 17 more parts), 8 R/C
rotations normalized 180->0 / 270->90 (unpolarized only, pad angles kept
consistent), TOL 1.0mm
- IGN divider: Rigb1 10k -> 3.3k in sch+board (24V ign -> 3.13V at PA5, FT-pin
safe incl. 35V transients; was 7.5V, out of spec). Fleet rework note: same
swap recommended on the 10 EinarBoard 1.0 units
- Leo's 46 track segments byte-identical through both passes; 0 courtyard
conflicts; parens balanced
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01GSKKes8GsS4YHAMWJ44tCm