v6 T4c: ERC fixes - RF_IN retyped passive, PF18 PWR_FLAG on SIM_VDD
Leo's ERC flagged exactly two errors after the T4 sync:
1. U18 pin 2 RF_IN [Input] undriven - my hand-built ZED-F9P symbol typed the RF port as a
logic input. RF ports are conventionally passive; retyped in Drogheda-sym AND the
schematic's lib_symbols cache (1 substitution each, asserted). Its real connection
arrives with the Block S bias tee in T6.
2. U22 pin 1 VCC [Power input] undriven - SIM_VDD is fed by the modem's USIM1_VDD, whose
EasyEDA pin type is not a power output. Idiomatic fix: PF18 PWR_FLAG on SIM_VDD,
consistent with PF1-PF17.
Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YJ4eAB6zjQT49RVwpgfKdt
This commit is contained in:
parent
4f6e1bb347
commit
4b8bdf4916
@ -1048,7 +1048,7 @@
|
|||||||
(effects (font (size 1.27 1.27)))
|
(effects (font (size 1.27 1.27)))
|
||||||
)
|
)
|
||||||
)
|
)
|
||||||
(pin input line
|
(pin passive line
|
||||||
(at -33.02 7.62 0)
|
(at -33.02 7.62 0)
|
||||||
(length 5.08)
|
(length 5.08)
|
||||||
(name "RF_IN"
|
(name "RF_IN"
|
||||||
|
|||||||
File diff suppressed because it is too large