Drogheda/03-Architecture-Hardware/kicad/hbox-watchdog-v5.kicad_dru

19 lines
703 B
Plaintext

(version 1)
(rule "Minimum clearance 1"
(constraint clearance (min 0.15mm))
(condition "A.NetClass != 'HV24' && B.NetClass != 'HV24'")
)
(rule "HV24 clearance"
(constraint clearance (min 0.5mm))
(condition "(A.NetClass == 'HV24' || B.NetClass == 'HV24') && !(A.Type == 'Pad' && B.Type == 'Pad' && A.memberOfFootprint('U2') && B.memberOfFootprint('U2'))")
)
(rule "HV24 exception: MP1584EN land pattern"
(constraint clearance (min 0.15mm))
(condition "A.Type == 'Pad' && B.Type == 'Pad' && A.memberOfFootprint('U2') && B.memberOfFootprint('U2')")
)
(rule "Minimum text height and thickness 1"
(layer "F.Silkscreen")
(constraint text_height (min 0.5mm))
(constraint text_thickness (min 0.1mm))
)