Drogheda/03-Architecture-Hardware/cabinet-electrical-bom.md

78 lines
4.8 KiB
Markdown
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

# Cabinet Electrical BOM — the box the HBOX lives inside
**Source:** `Selección de componentes para gabinete2.xlsx` (Helgen, 2026-06)
**Date captured:** 2026-06-19
**Key point:** the HBOX is **not** mounted bare on a machine — it sits **inside an
industrial electrical cabinet (gabinete)** with DIN-rail power and protection
components. This BOM is that cabinet. It is **productized across voltages** (12 /
24 / 48 / 110 / 230 V machines) and **across multiple port terminals** (ICAVE,
Hutchison, TIMSA, EIT, LCT) — i.e. this is heading to **hundreds of cabinets**, so
the fixes must be production-grade and repeatable. *(Pricing/margins omitted here —
see the sheet.)*
---
## Nested-enclosure architecture (important for thermal)
```
Machine power (12/24/48/110/230 V) + ignition
│
▼ ┌──────────────── Gabinete IP67 (ABS, Yetlebox P3901, 39×29×16 cm) ───────────┐
breaker │ DIN rail · terminals · SPD · fuse holder · SSR/opto (ignition sense) │
+ SPD ──►│ Mean Well DDR-60G-24 ──► clean 24 Vdc ─────────────┐ (supply dissipates │
│ │ heat *inside* box) │
│ ┌────────── HBOX (3D-printed ASA, sealed) ────────┼───┐ │
│ │ PowerBoost 1000C + LiPo · simpleRTK2B+4G · STM32 watchdog │ │
│ └───────────────────────────────────────────────────┘ │
└───────────────────────────────────────────────────────────────────────────┘
```
Two sealed boxes, one inside the other, **with a 60 W-class power supply generating
heat in the outer one**, in full sun. See the thermal note in
`03-Architecture-Hardware/hardware-respec-and-pcb-brief.md` §thermal.
---
## Cabinet catalog (Helgen final selection, by machine voltage)
| Function | 12 V | 24 V | 48 V | 110–230 V |
|---|---|---|---|---|
| **Enclosure (IP67, ABS)** | Yetlebox P3901 | P3901 | P3901 | P3901 |
| DIN rail | Weidmüller TS 35×7.5 | ← | ← | ← |
| Neutral terminals ×5 | Weidmüller WDU 2.5 PA/VI | ← | ← | ← |
| Ground terminals | Weidmüller WPE4 | ← | ← | ← |
| Fuse-holder terminal ×3 | Phoenix Contact 3212166 **PT 6-FSI/C** (blade) | ← | ← | ← |
| Ignition isolation (SSR / opto) | Weidmüller **MOS 12-28VDC** | Weidmüller **TOS 24VDC 2A** | Wago **859-744** | IDEC **RV8S-L-D24-A120** |
| Surge protection (SPD) | Phoenix **TTC-6-TVSD-C-12DC-PT-I** | …**-24DC-** | …**-48DC-** | Phoenix DC + Total Ground **A2021** (AC) |
| Breaker | Phoenix **TMC 81C 05A** (5 A) | ← | ← | Schneider **A9F74202** (2 A, AC) |
| **Power supply → 24 Vdc** | Mean Well **DDR-60G-24** | Mean Well **DDR-60G-24** | Mean Well **DDR-60L-24** | Siemens **6EP1332-1LB00** (SITOP) |
Output rail in all cases: **24 Vdc, ~2.4 A, 60 W**.
---
## What this means for the fix (engineering read)
1. **The cabinet's power & protection are already industrial-grade.** Surge
suppression (Phoenix TVS/SPD), a breaker, isolated ignition sensing (SSR/opto),
and a quality regulated supply (Mean Well / Siemens) are present at the cabinet
level. **The HBOX PCB does NOT need to re-implement input surge/breaker** — it
can assume a **clean 24 Vdc feed** and an **isolated ignition signal**. That
simplifies the HBOX redesign (see hardware brief).
2. **So the weak link is confirmed to be inside the HBOX**, exactly where the
client pointed: PowerBoost 1000C + LiPo + Dupont — not
the cabinet (the **ASA enclosure** is adequate). The HBOX-internal job is **24 V → 5 V (robust buck) + watchdog +
the RTK stack**, with the LiPo decision (drop/replace) still open.
3. **Verify the actual fuse value.** The PT 6-FSI/C is a *holder*; the fitted blade
fuse rating is what matters for the client's "under-rated fuse" concern — read
the installed fuse and compare to the measured worst-case + inrush.
4. **The Mean Well runs hot inside a sealed box.** At 60 W class it dissipates
several watts continuously; that heat has nowhere to go in a sealed ABS IP67
cabinet → it raises the ambient the HBOX (and its 18650 + boost + modem) must
survive. This is now a **primary thermal driver**, not just solar load.
> Open question for Leo to confirm: does the HBOX receive the cabinet's **24 V**
> (then step down internally), or the raw machine voltage? The BOM implies a clean
> 24 V feed + isolated ignition — confirm so the HBOX power redesign targets the
> right input.