Drogheda/03-Architecture-Hardware/hardware-respec-and-pcb-brief.md

16 KiB
Raw Blame History

Hardware Re-spec + Watchdog PCB Brief

Date: 2026-06-19 · Owner: Leo Rodriguez (Helgen) Strategy (Leo's call): phased — ship a ruggedized interim to the fleet now (Phase 1), design the production PCB in parallel (Phase 2). Drivers: the RCA (06-Testing-Validation/RCA-2026-06-field-failures.md) and the ICAVE client review (prototype-grade, vibration, connectors, thermal, 4G failures).

This is an engineering brief, not a finished schematic. Specific part numbers are starting points to price/validate — confirm against the measured power budget (see §2) and your supplier availability.


1. Design requirements (the bar the fix must clear)

Context update (2026-06-19): the HBOX sits inside an industrial cabinet that already provides surge protection, a breaker, isolated ignition sensing, and a regulated 24 Vdc supply (Mean Well DDR-60G-24) — see 03-Architecture-Hardware/cabinet-electrical-bom.md. So the HBOX can assume a clean 24 V feed and need not re-implement input surge/reverse-polarity. The redesign focus narrows to: 24 V→5 V, the watchdog, the LiPo decision, and — now the top issue — thermal management (see §thermal).

Requirement Target Why
Operating temp −10…+75 °C internal, survive +85 °C sealed ASA box inside a sealed ABS IP67 cabinet that also holds the heat-dissipating Mean Well supply, in full sun
Enclosure material ASA (current) — keep; UV-stable, ~95–100 °C confirmed ASA (not PLA): margin over the cabinet interior; the case is not the liability
Input voltage clean ~24 V from the cabinet (design the buck 9–36 V for margin) cabinet's Mean Well already regulates; isolated ignition provided
Surge/transient handled at cabinet level (Phoenix SPD + breaker); HBOX keeps a modest TVS don't duplicate the cabinet's protection
Vibration survive continuous machinery vibration no Dupont, locking connectors, retained boards
Ingress IP67 maintained, no internal condensation coastal humidity; sealing constrains cooling (§thermal)
5 V rail ≥3 A continuous, handle LTE TX bursts (~2 A) modem peaks brown out a 1 A hobby boost
Maintainability SIM swap without disassembly; labeled, keyed client point #5
Serviceability one PCB, documented, test points, repeatable "apt for production"
Observability log temp + battery + link health prove failures in the field

2. First, measure the power budget (blocks everything)

Before choosing a DC-DC or fuse, bench-measure the stack on the actual hardware:

  • Idle, 1 Hz, and LTE-TX-burst current at 5 V (modem bursts are the spike).
  • Inrush at power-on (caps + modem).
  • Repeat at 12 V and 24 V input.

Expected ballpark (validate): avg ~0.3–0.6 A @5 V, bursts 1.5–2 A during LTE transmit. That burst is almost certainly beyond the PowerBoost 1000C's ~1 A continuous rating — a strong candidate for both the instability and the "under-rated fuse" the client flagged. Everything below assumes ~2.5 A peak @5 V; correct it once measured.


2b. Thermal & enclosure — now the #1 physical fix

The problem is a nested thermal trap. A sealed ASA HBOX sits inside a sealed ABS IP67 cabinet that also contains the Mean Well supply (60 W class, dissipating several watts continuously), in full Veracruz sun. Two failure drivers stack:

  • The ASA shell is not the problem. ASA is UV-stable and softens at ~95–100 °C, with margin over the cabinet interior, so the HBOX shell will not sag/warp at these temperatures. (Corrects an earlier PLA assumption.)
  • The LiPo is in that same hot space (charge limit 45 °C) → degradation, swelling, voltage sag → brownout.

About adding a fan — read this first

A fan inside a sealed IP67 box does almost nothing. It only stirs the same trapped air; with no path to outside air, no heat actually leaves the box (it even adds a little). Cooling requires either moving heat out by conduction or exchanging air with the outside — and air exchange breaks IP67, which in a salty, humid, dusty port invites corrosion. So:

Option Removes heat? Keeps IP67? Verdict
Internal fan only (sealed) ✗ (just stirs air) ✓ Don't bother
Filtered vents + extractor fan ✓ ✗ (→ ~IP54) Only with filters + maintenance; risky in this environment
Conduction: mount hot parts to a metal plate / metal enclosure ✓✓ ✓ Best — heatsink to the outside, stay sealed
Reduce solar gain (white/reflective, sunshade, relocate out of sun) ✓ ✓ Cheap, do it now
Reduce internal generation (efficient DC-DC, remove LiPo) ✓ ✓ Do it
Gore pressure-vent ✗ (condensation only) ✓ (membrane) Keep for humidity, not for cooling
Active (Peltier / vortex / heat-exchanger) ✓ ✓ Overkill/expensive — last resort

Recommended thermal strategy (sealed, no IP compromise):

  1. Keep the ASA enclosure (UV-stable, ~95–100 °C — adequate). Optionally move to metal for extra heatsinking, or eliminate the inner box and mount the PCB directly to the cabinet plate.
  2. Conduct heat out: bolt the DC-DC (and the new HBOX board's hot spots) to the cabinet's metal mounting plate / gland plate, or move to a metal (aluminium) cabinet that acts as a heatsink. Use thermal pads/gap-filler.
  3. Cut the solar load: white/reflective cabinet, a sunshade, and mount out of direct sun where the machine allows.
  4. Cut internal heat: a higher-efficiency 24 V→5 V buck and removing the LiPo both lower the steady-state interior temperature.
  5. Quantify it: put a thermocouple/logger inside a representative cabinet for a full sunny shift — design to the measured number, not a guess.

3. Phase 1 — Interim ruggedization (do now, on existing modules)

Goal: stop the bleeding on the deployed fleet without waiting for a PCB. All of this is achievable with off-the-shelf parts and rework.

  1. Kill the Dupont jumpers. Replace every jumper with locking, keyed connectors — JST-XH (signal) / Molex Micro-Fit 3.0 (power). Crimped, not hand-twisted. This alone removes the #1 vibration intermittent.
  2. Replace the PowerBoost 1000C with an industrial DC-DC stepping the cabinet's 24 V → 5 V, ≥3 A (e.g., a sealed Mornsun/Recom module or a TI LMR33630-class buck for the LTE bursts). Design the input wide (9–36 V) for margin, but the normal feed is the cabinet's clean 24 V. Sized from §2.
  3. Resolve the battery (decision — see §6). At minimum relocate the LiPo to the coolest wall, away from the modem/DC-DC, and add a temperature cutoff; better, replace it with LiFePO4 or a supercap hold-up, or drop battery mode if the client doesn't need parked tracking.
  4. Verify the cabinet fuse. Read the blade fuse fitted in the Phoenix PT 6-FSI/C holder and compare to the measured worst-case + inrush — this is the "under-rated fuse" the client flagged. Surge/breaker are already handled at the cabinet (Phoenix SPD + breaker); the HBOX keeps only a modest local TVS.
  5. Mechanical lockdown. Mount each board on standoffs with vibration isolators/grommets; retain the simpleRTK2B + 4G master in their sockets with a bracket or retention clip; thread-lock + torque the SMA bulkheads.
  6. Conformal-coat the watchdog/discrete wiring (acrylic or urethane) against humidity and to stabilize solder joints under vibration.
  7. Thermal quick wins (see §2b — do NOT add an internal fan to a sealed box): keep the ASA inner box (adequate) or remount the boards on the metal plate; cut solar gain (white/reflective cabinet + sunshade, relocate out of sun); conduct the DC-DC/modem heat to the cabinet's metal plate; keep a Gore-style pressure-vent for condensation only.
  8. SIM access: bring the SIM to a front-panel holder so swaps don't need teardown.
  9. Flash firmware v2 (thermal logging + proper 4G recovery) on every unit.
  10. Instrument at least one unit with an interior thermocouple log for a full sunny shift to quantify the thermal problem.

Phase 1 is the "permanent-enough" stabilization while Phase 2 is fabricated.


4. Phase 2 — Integrated Watchdog Carrier PCB (the real fix)

A single 4-layer, industrial-temp carrier board that replaces all the hand-wiring and the hobby power boards, and onto which the simpleRTK2B and 4G NTRIP Master mount via locking board-to-board (or retained XBee socket).

Block diagram

 Cabinet 24V (already SPD/breaker-protected) ─► [keyed plug]
   └► modest TVS + reverse-polarity FET ─► bulk cap
        └► DC-DC buck 24V→5V (design 9–36V), ≥3A ─► 5V rail
             ├► STM32 watchdog (3.3V LDO) ── UART ──► simpleRTK2B RX1 (UBX)
             │      ├ sense: Vin, 5V, battery dividers (filtered)
             │      ├ status LED + SWD header + debug UART (dashboard)
             │      └ optional: 4G modem health/RESET line, RTC
             ├► high-side LOAD SWITCH / eFuse ─► switched 5V ─► simpleRTK2B + 4G stack
             └► hold-up: supercap bank OR LiFePO4 charger (see §6)
 Antennas: bulkhead SMA pigtails (GNSS L1/L2 + LTE) · SIM: front-panel holder/MFF2

Key design choices vs the current discrete design

Current (discrete) PCB replacement Benefit
2N3904 + IRF9540N + 10 k pull-up integrated high-side load switch / eFuse (e.g., TPS25200 / TPS2596 / load-switch IC) current-limited, fewer parts, defined turn-on, no gate-pull-up gotchas
PowerBoost 1000C automotive buck ≥3 A + protection front-end survives LTE bursts, wide Vin, transient-tolerant
LiPo in hot box supercap hold-up or LiFePO4 (or none) removes the thermal/safety liability
ASA inner box (UV-stable, ~95–100 °C) keep (adequate); optional metal for extra heatsinking, or mount PCB to the cabinet plate survives the cabinet's internal temperature
Dupont + screw terminals locking JST/Molex + pluggable terminal block vibration-proof
Bare boards loose in box retained board-to-board + isolated standoffs no movement, no solder flex
SIM buried in stack front-panel SIM or MFF2 eSIM client point #5 solved
No local protection modest TVS + RP FET (cabinet has the SPD/breaker) survives without duplicating the cabinet
No temp/observability MCU temp + sense dividers + test points provable diagnostics

Board-level details to specify

  • Protection front-end (light — the cabinet does the heavy lifting): the cabinet already provides surge (Phoenix SPD) + breaker + isolated ignition. The HBOX board needs only a reverse-polarity P-FET and a modest TVS on its 24 V input — don't duplicate the cabinet's SPD/eFuse.
  • DC-DC: qualify input 9–36 V; ≥3 A @5 V; good thermal pad to a copper pour / enclosure; spread-spectrum or proper filtering for GNSS RF cleanliness (switcher noise can hurt the L1/L2 front-end — keep it away from the antenna feed and filter it).
  • MCU: keep STM32F411 to reuse v2 firmware, or step to an automotive/industrial-temp STM32 (G0/L4). Bring out SWD + a debug UART for the dashboard. Add the internal-temp logging already in v2; consider an external temp sensor near the LiPo/modem.
  • GNSS RF integrity: keep the switcher and digital noise away from the GNSS antenna trace; solid ground plane; the ZED-F9P front-end is sensitive — this protects fix quality (and therefore the watchdog's view of "link health").
  • Connectors: all locking/keyed; bulkhead SMA with lock washers; a single keyed vehicle-power plug.
  • Mechanical: mounting holes with vibration isolators; design for conformal coat or selective potting of the power section.
  • DFM/serviceability: silkscreen labels, test points on every rail + UART, a fab/assembly package, and a documented BOM (this is literally the "apt for production" the client asked for).

5. Indicative BOM (validate prices/availability/temp grade)

Function Interim (Phase 1) PCB (Phase 2)
DC-DC 24→5 V ≥3 A Recom/Mornsun/TI buck module TI LMR33630-class on-board buck
Load switch keep NPN+P-FET (retained) TPS25200 / TPS2596 / load-switch IC
Input protection modest TVS + RP diode (cabinet has SPD/breaker) RP FET + modest TVS on-board
Hold-up / battery relocate LiPo + temp cutoff supercap bank or LiFePO4 charger
Inner enclosure ASA — keep (adequate); or mount to plate metal box / mount PCB to cabinet plate
MCU existing Blackpill STM32F411 (or G0/L4) on-board
Interconnect JST-XH / Molex Micro-Fit board-to-board + locking I/O
Antennas re-torque bulkhead SMA bulkhead SMA pigtails
SIM front-panel holder front-panel holder or MFF2 eSIM
Coating acrylic conformal coat conformal coat / pot power section
Thermal sunshade + conduct heat to metal plate (no internal fan) metal cabinet as heatsink; sealed (keep IP67)

6. Open decisions for Leo (these change the design)

  1. Battery mode — keep, change, or drop?
    • Keep tracking while the vehicle is off (anti-theft / parked location)? Then use LiFePO4 (wider temp, safer) or a relocated/temperature-managed cell — not a LiPo baking next to the modem.
    • Only need ride-through across brief power dips? A supercap hold-up is simpler, safer, and temperature-tolerant — but won't give long parked tracking.
    • Vehicle-only acceptable? Drop the battery entirely — removes the single worst thermal/safety liability. (Recommended if the client doesn't require parked tracking — confirm with ICAVE.)
  2. SIM strategy: swappable front-panel SIM vs MFF2 eSIM (eliminates the swap problem but commits the carrier). Depends on how often SIMs change.
  3. MCU: reuse F411 (fast, keeps v2 firmware) vs move to an industrial-temp STM32 (more margin, small port effort).
  4. Inner enclosure material: confirmed ASA (UV-stable, ~95–100 °C) — adequate for the nested-cabinet temperatures; no material change required. Optionally eliminate the inner box and mount the PCB to the cabinet plate for better conduction.
  5. Cabinet thermal path: keep ABS IP67 + sunshade + conduct heat to a metal plate, or move to a metal (aluminium) cabinet as a heatsink (best, costs more). An internal fan in a sealed box is not a fix (see §2b) — only conduction or (IP-breaking) ventilation removes heat.
  6. Make vs buy the modem: keep the ArduSimple 4G NTRIP Master, or move to a qualified industrial LTE module with a known wide-temp rating.

7. Suggested next actions (feeds PLAN.md)

  • Bench power-budget + inrush measurement (§2) → picks the 24→5 V buck.
  • Quantify cabinet temperature (thermocouple in a representative cabinet, full sunny shift) → design target for §2b.
  • Decide §6.1 (battery), §6.4 (inner-box material), §6.5 (cabinet thermal path) — the biggest levers. The ASA enclosure is adequate — no material swap needed; focus on the conduction path + active thermal.
  • Phase-1 ruggedization kit BOM + rework one unit as the reference build.
  • Phase-2 schematic → layout → fab/assembly; pilot 2–3 boards before fleet.
  • Cabinet BOM is industrial-grade and stays — see 03-Architecture-Hardware/cabinet-electrical-bom.md.